Soluciones de medida EMC

Disturbance Voltage Measurements
  Frequency Use E Use H Use V Use I Use P
R&S®ENV216 Two-Line V-Network R&S®ENV216 Two-Line V-Network
For disturbance voltage measurements on single-phase EUTs
9 kHz - 30 MHz X
R&S®ESH2-Z5 V-Network, 4 lines, 25 A R&S®ESH2-Z5 V-Network, 4 lines, 25 A
for RFI voltage measurements on three-phase EUTs
9 kHz - 30 MHz X
R&S®ENV4200 V-Network, 4 lines, 200 A R&S®ENV4200 V-Network, 4 lines, 200 A
for RFI voltage measurements at high currents
150 kHz - 30 MHz X
R&S®ESH3-Z6 Single-Line V-Network, 100 A R&S®ESH3-Z6 Single-Line V-Network, 100 A
100 kHz to 200 MHz
100 kHz - 200 MHz X
R&S®EZ-4 Control Cable, 3 m, ESIBx, ESPIx–ESH3-Z5
X
R&S®EZ-5 Control Cable, 10 m, ESIBx, ESPIx–ESH2-Z5
X
R&S®EZ-6 Control Cable, 10 m, ESIBx, ESPIx–ESH3-Z5
X
R&S®EZ-13 Control Cable, 2 m, ESxS–ESH2-Z5
X
R&S®EZ-14 Control Cable, 2 m, ESxS–ESH3-Z5
X
R&S®EZ-21 Control Cable, 3 m
ENVxxx to ESIB, ESPI, ESCI, ESU, ESL
X
R&S®EZ-21 Control Cable, 10 m
ENVxxx to ESIB, ESPI, ESCI, ESU, ESL
X
R&S®EZ-27 Adapter for LISN control cable
Required to connect R&S®EZ-21 and R&S®ESL
X
R&S®ENY21 Coupling Network R&S®ENY21 Coupling Network
For radio disturbance and immunity measurements on unshielded, symmetrical telecommunications ports
150 kHz - 30 MHz X
R&S®ENY41 Coupling Network R&S®ENY41 Coupling Network
For radio disturbance and immunity measurements on unshielded, symmetrical telecommunications ports
150 kHz - 30 MHz X
R&S®ENY81 Coupling Network R&S®ENY81 Coupling Network
For radio disturbance measurements on unshielded, symmetrical telecommunications ports
150 kHz - 30 MHz X
R&S®ENY81-CA6 Coupling Network R&S®ENY81-CA6 Coupling Network
For radio disturbance and immunity measurements on telecommunications ports
X
R&S®ESH2-Z2 Active Voltage Probe R&S®ESH2-Z2 Active Voltage Probe
The active voltage probe is used for measuring RFI voltages on lines that do not carry AC supply voltage.
9 kHz - 30 MHz X
R&S®ESH2-Z3 Passive Voltage Probe R&S®ESH2-Z3 Passive Voltage Probe
The passive voltage probe is suitable for measuring RFI voltages (on AC supply lines) to CISPR16-2-1 and EN55016-2-1.
9 kHz - 30 MHz X
R&S®ESH2-Z31 Attenuator for ESH2-Z3
For checking the interference source impedance to EN55016-2-1 and CISPR16-2-1
9 kHz - 30 MHz
R&S®ESH3-Z2 Pulse Limiter R&S®ESH3-Z2 Pulse Limiter
High RF input levels and high-energy interfering pulses generated on artificial mains networks when the DUT is switched on and off can damage the RF input circuits of test receivers. The R&S®ESH3-Z2 pulse limiter limits and reduces the interference level.
0 Hz - 30 MHz X
R&S®EZ-12 Antenna Impedance Converter R&S®EZ-12 Antenna Impedance Converter
for interference measurements on vehicle antennas to CISPR25
150 kHz - 30 MHz X
R&S®EZ-25 150 kHz Highpass Filter R&S®EZ-25 150 kHz Highpass Filter
For conducted emission measurements in the presence of high longwave mains disturbance signals
150 kHz - 30 MHz X
Disturbance Current Measurements
  Frequency Use E Use H Use V Use I Use P
R&S®EZ-17 Current Probe R&S®EZ-17 Current Probe
Electromagnetic emission and susceptibility measurements in the range 5 Hz to 100 (200) MHz
20 Hz - 100 MHz X
R&S®ESV-Z1 VHF Current Probe
R&S®ESV-Z1 current probe is used for selective or broadband measurement of very small as well as of very large RF currents in electric lines. They are shielded against electrostatic effects and comply with CISPR16-1-2 and VDE0876.
9 kHz - 600 MHz X
Disturbance Power Measurements
  Frequency Use E Use H Use V Use I Use P
R&S®MDS-21 Absorbing Clamp R&S®MDS-21 Absorbing Clamp
Measurement of disturbance power and screening effectiveness on cables
30 MHz - 1000 MHz X
R&S®EZ-24 Ferrite Clamp R&S®EZ-24 Ferrite Clamp
Reproducible measurements of disturbance field strength and disturbance power
1000 kHz - 1000 MHz X
Field-strength Measurements
  Frequency Use E Use H Use V Use I Use P
R&S®HZ-14 Probe Set for E and H Near-field Measurements R&S®HZ-14 Probe Set for E and H Near-field Measurements
Detecting EMC trouble spots
9 kHz - 1000 MHz X X
R&S®HZ-15 Probe Set R&S®HZ-15 Probe Set
for E and H near-field emission measurements with test receivers and spectrum analyzers
30 MHz - 3 GHz X X
R&S®HZ10 Shielded, calibrated Pickup Coil (MIL) R&S®HZ10 Shielded, calibrated Pickup Coil (MIL)
Measurement of magnetic field strengths to military standards
5 Hz - 10 MHz X
R&S®HFH2-Z2 Loop Antenna R&S®HFH2-Z2 Loop Antenna
Broadband active loop antenna for measuring the magnetic field-strength
9 kHz - 30 MHz X
R&S®HFH2-Z6 Rod Antenna (MIL)
Broadband active rod antenna for measuring the electrical component of radiated EMI in test setups to MIL-STD-461/462 and similar MIL standards and CISPR25.
9 kHz - 30 MHz X
R&S®HL033 Antenna R&S®HL033 Antenna
Log-Periodic Antenna
80 MHz - 2 GHz X
R&S®HL223 Antenna R&S®HL223 Antenna
Log-Periodic Antenna
200 MHz - 1.3 GHz X
R&S®HL040 Antenna R&S®HL040 Antenna
Log-Periodic Dipole Antenna
400 MHz - 3.6 GHz X
R&S®HL050 Antenna R&S®HL050 Antenna
Log-Periodic Antenna
850 MHz - 26.5 GHz X
R&S®HM020 Antenna R&S®HM020 Antenna
Triple-Loop Antenna
9 kHz - 30 MHz X
R&S®HM525 Antenna R&S®HM525 Antenna
Active H-Field Measurement Antenna
100 Hz - 30 MHz X
R&S®AM524 Antenna R&S®AM524 Antenna
Low-noise Active Antenna System
100 Hz - 1000 MHz X
R&S®HK116 Antenna R&S®HK116 Antenna
Biconical Antenna
20 MHz - 300 MHz X
R&S®HF907 Antenna R&S®HF907 Antenna
Double-Ridged Waveguide Horn Antenna
800 MHz - 18 GHz X
R&S®HL562 Antenna R&S®HL562 Antenna
ULTRALOG
30 MHz - 3 GHz X
R&S®HE202 Antenna R&S®HE202 Antenna
Active Receiving Dipole
200 MHz - 1000 MHz X
R&S®HE302 Antenna R&S®HE302 Antenna
Active Receiving Dipole
20 MHz - 500 MHz X
R&S®HE300 Antenna R&S®HE300 Antenna
Active Directional Antenna
20 MHz - 7.5 GHz X
R&S®HE300 Antenna R&S®HE300 Antenna
Active Directional Antenna
R&S®HZ-3 Supply Cable, 3 m
for Active Antennas HFH2-Z1/-Z2/-Z6 and Test Receiver
X X
R&S®HZ-4 Supply Cable, 10 m
for Active Antennas HFH2-Z1/-Z2/-Z6 and Test Receiver
X X
R&S®HFU2-Z4 RF Connecting Cable, 12m
N-type, common mode suppression
X
R&S®HFU2-Z5 RF Connecting Cable, 7m
N-type, common mode suppression
X
R&S®EZ-19 RF Adapter Cable, 0.2 m
Coax-type, BNC/Twinax connectors, for HZ-10
X X
Tripods and Positioning Devices
  Frequency Use E Use H Use V Use I Use P
R&S®HFUZ Tripod
X
R&S®HZ-1 Wooden Tripod
for Test Antennas HFH2-Z6, HK116, HL223 and HUF-Z4
X
Additional Accessories
  Frequency Use E Use H Use V Use I Use P
R&S®FSE-Z4 DC Block
10 kHz to 18 GHz
10 kHz - 18 GHz X X X X X
R&S®HZ-9 Power Supply R&S®HZ-9 Power Supply
For active antennas and EMI accessories
X X X
R&S®RAM Matching Pad, 50 Ω/75Ω R&S®RAM Matching Pad, 50 Ω/75< >Ω
bidirectional, 0 Hz to 2.7 GHz, N female/N male connectors, load capacity 2 W, L section
0 Hz - 2.7 GHz X X X X X
R&S®RAZ Matching Pad, 50 Ω/75 Ω R&S®RAZ Matching Pad, 50 Ω/75 Ω
0 Hz - 2.7 GHz X X X X X
R&S®PSA-Z2 Standard keyboard
Keyboards for FSEx, ESIBx (german or english)
R&S®RBU50 High-Power Attenuator,
50 W

0 Hz to 2 GHz
0 Hz - 2 GHz X X X X X
R&S®RBU100 High-Power Attenuator, 100 W
0 Hz to 2 GHz
0 Hz - 2 GHz X X X X X
R&S®RDL50 High-Power Attenuator,50 W R&S®RDL50 High-Power Attenuator,
50 W

0 Hz to 6 GHz, 20 dB
0 Hz - 6 GHz X X X X X
R&S®ZZA-478 19" adapter
4 HU, 7/8, for BW 2000 cabinets
R&S®ZZA-411 19" Rack Adapter
4 HU, 1/1, for BW2000 cabinets
R&S®ZZA-95 19" adapter, 5 HU, 1/1, for KB 90 cabinets (R&S ESIB)
R&S®PCK IEC/IEEE-Bus Cables, 1m or 2 m
The cables are highly screened for low radiated interference.